This is a simplified HHO flow meter

This device should give the HHO Experimenter a 'semi-standardized' tool that they can use to measure their cell performance as they tweak and adjust them.

It is intended to be used with comparison testing between runs and modifications. So there should be no question as to whether or not the last "tweak" you made to your cell had a positive or negative result.

It is very easy to make. If damaged it, just swing by the convenience store and pick one up of the same brand and size as you had before. If the cap is not damaged, you can reused the cap on the new bottle.

It is not near as complicated and as hard to replicate as the 'chimney' hhometers and 'bouncing ball' flow meters that most everyone else is using.

And it should give anyone that uses one a very easy repeatable and consistent standard to measure the gas output from their cells.

Important Usage Notes:

- You start your stop watch when the first bubble is released inside the bottle.

- You stop your stop watch when all the water has been evacuated and gas starts to bubble out of the small hole in the cap.

- The small evacuation hole MUST be the lowest point in the chamber, especially during the last inch of water to be evacuated.

- The bottle MUST remain floating unsupported in the water tank with the exception that it must be held almost vertical right at the end of the test.

- In all cases, the water level inside the chamber must remain level with the water level in the tank. (bottle remains floating even when supported vertically at the end of the test.)

- It is suggested that you allow some water to back fill the tube. This is to allow you to turn on or hook up your cell and prepare yourself to press the button on the stopwatch.

- The volume of liquid you are evacuating WILL ALWAYS be the same (unless you crush or deform the bottle). [Atmospheric pressure issues not withstanding]

- The size of the bottle used is not relevant unless you are testing for large volume production. In that case you may need to utilize a larger bottle.

- The actual volume of water that would have been evacuated in this particular configuration is approximately 540 ml.(+/- 5 ml). The total volume of water you evacuate WILL vary.

  1. Categories: Science & Tech
Comments on

Simplified HHO Flow Meter

12 Comments | Add Comment
  • lol

    redneck foker

    By meinfury 1230251993 Reply Spam Moderate Up Moderate Down
  • I bought a F-16 ...

    I bought a F-16 Pulse King on ebay and my HHO went crazy. I believe they are experimenting with this in now.

    By hho1junkie [Affiliate User] 1228589434 Reply Spam Moderate Up Moderate Down
  • Luther, excellent ...

    Luther, excellent and absolutely brilliant idea using a single bottle as a "constant"...you basically stopped me from labouriosly constructing an hhometer from scratch....thank you

    By bhelpurii [Affiliate User] 1227960916 Reply Spam Moderate Up Moderate Down
  • Your welcome. Keep ...

    Your welcome.

    Keep in mind that this suggestion is only intended to help make your readings more a bit consistent and repeatable.

    You don't want to accidentally miss out on that 'better' design or configuration just because you messed up on one of your readings.

    By lutherp40 [Affiliate User] 1227565764 Reply Spam Moderate Up Moderate Down
  • Thank you, you made ...

    Thank you, you made this very clear.
    I now know how to make accurate measurements.

    By showme2learn [Affiliate User] 1227198234 Reply Spam Moderate Up Moderate Down
  • Why not simply push ...

    Why not simply push the tube all the way to the bottom of the bottle, fill the latter with water, and see how fast the HHO empties the bottle through the small hole?

    By joebtflsk [Affiliate User] 1225462128 Reply Spam Moderate Up Moderate Down
  • You are most ...

    You are most welcome.

    I am only glad I had something here worth watching for somebody. :)

    By lutherp40 [Affiliate User] 1218285836 Reply Spam Moderate Up Moderate Down
  • Good idea. I need ...

    Good idea. I need to get some output test info on mine. Thanks for taking the time to share.

    By pat1huey [Affiliate User] 1218137808 Reply Spam Moderate Up Moderate Down
  • Thx good idea now I ...

    Thx good idea now I have a Idea how to measure mine.

    By bsacheli [Affiliate User] 1217376770 Reply Spam Moderate Up Moderate Down
  • good job.

    good job.

    By KyHighlander59 [Affiliate User] 1216919539 Reply Spam Moderate Up Moderate Down
  • Which generator are ...

    Which generator are you talking about? I have many.

    The one in the video is a simple 5 wallplate plate, 2 pole, sealed sides, wired +nnn-

    Its only purpose is to be a "standard" so I can compare changes in solutions, temperature, tank configurations, etc. etc. using a singe set of plates.

    Too many changes all at once make it difficult to figure out what actually helped your production.

    In this video it was only pulling about 2 or 3 amps at 12.1 VDC brute force.

    By lutherp40 [Affiliate User] 1216910506 Reply Spam Moderate Up Moderate Down
  • Very interesting ...

    Very interesting setup. How many amps is your generator pulling?

    By tcvaldez [Affiliate User] 1216909345 Reply Spam Moderate Up Moderate Down