International
This is a simplified HHO flow meter
This device should give the HHO Experimenter a 'semi-standardized' tool that they can use to measure their cell performance as they tweak and adjust them.
It is intended to be used with comparison testing between runs and modifications. So there should be no question as to whether or not the last "tweak" you made to your cell had a positive or negative result.
It is very easy to make. If damaged it, just swing by the convenience store and pick one up of the same brand and size as you had before. If the cap is not damaged, you can reused the cap on the new bottle.
It is not near as complicated and as hard to replicate as the 'chimney' hhometers and 'bouncing ball' flow meters that most everyone else is using.
And it should give anyone that uses one a very easy repeatable and consistent standard to measure the gas output from their cells.
Important Usage Notes:
- You start your stop watch when the first bubble is released inside the bottle.
- You stop your stop watch when all the water has been evacuated and gas starts to bubble out of the small hole in the cap.
- The small evacuation hole MUST be the lowest point in the chamber, especially during the last inch of water to be evacuated.
- The bottle MUST remain floating unsupported in the water tank with the exception that it must be held almost vertical right at the end of the test.
- In all cases, the water level inside the chamber must remain level with the water level in the tank. (bottle remains floating even when supported vertically at the end of the test.)
- It is suggested that you allow some water to back fill the tube. This is to allow you to turn on or hook up your cell and prepare yourself to press the button on the stopwatch.
- The volume of liquid you are evacuating WILL ALWAYS be the same (unless you crush or deform the bottle). [Atmospheric pressure issues not withstanding]
- The size of the bottle used is not relevant unless you are testing for large volume production. In that case you may need to utilize a larger bottle.
- The actual volume of water that would have been evacuated in this particular configuration is approximately 540 ml.(+/- 5 ml). The total volume of water you evacuate WILL vary.
I bought a F-16 Pulse King on ebay and my HHO went crazy. I believe they are experimenting with this in now.
By hho1junkie [Affiliate User] 1228589434 Reply Spam [+0] Moderate Up Moderate Down RemoveLuther, excellent and absolutely brilliant idea using a single bottle as a "constant"...you basically stopped me from labouriosly constructing an hhometer from scratch....thank you
By bhelpurii [Affiliate User] 1227960916 Reply Spam [+0] Moderate Up Moderate Down RemoveYour welcome.
Keep in mind that this suggestion is only intended to help make your readings more a bit consistent and repeatable.
You don't want to accidentally miss out on that 'better' design or configuration just because you messed up on one of your readings.
Thank you, you made this very clear.
I now know how to make accurate measurements.
Why not simply push the tube all the way to the bottom of the bottle, fill the latter with water, and see how fast the HHO empties the bottle through the small hole?
By joebtflsk [Affiliate User] 1225462128 Reply Spam [+0] Moderate Up Moderate Down RemoveYou are most welcome.
I am only glad I had something here worth watching for somebody. :)
Good idea. I need to get some output test info on mine. Thanks for taking the time to share.
By pat1huey [Affiliate User] 1218137808 Reply Spam [+0] Moderate Up Moderate Down RemoveThx good idea now I have a Idea how to measure mine.
By bsacheli [Affiliate User] 1217376770 Reply Spam [+0] Moderate Up Moderate Down Removegood job.
By KyHighlander59 [Affiliate User] 1216919539 Reply Spam [+0] Moderate Up Moderate Down RemoveWhich generator are you talking about? I have many.
The one in the video is a simple 5 wallplate plate, 2 pole, sealed sides, wired +nnn-
Its only purpose is to be a "standard" so I can compare changes in solutions, temperature, tank configurations, etc. etc. using a singe set of plates.
Too many changes all at once make it difficult to figure out what actually helped your production.
In this video it was only pulling about 2 or 3 amps at 12.1 VDC brute force.
Very interesting setup. How many amps is your generator pulling?
By tcvaldez [Affiliate User] 1216909345 Reply Spam [+0] Moderate Up Moderate Down RemoveRated 3.86 | 420 Views
By agl01
Rated 4.17 | 2,198 Views
Affiliate Submitter: pazzosev
Rated 3.47 | 4,740 Views
By agl01
HHO Hydrogen Generator Dry Fuel Cell Video...How They Work
Rated 1.80 | 1,936 Views
Affiliate Submitter: agl00001
How To Install An Amp Meter DC Ammeter For...Hydrogen Generator
Rated 4.80 | 980 Views
By agl01
#54 Tall HHO Bubbler Construction Details
Rated 4.23 | 1,170 Views
Affiliate Submitter: ZeroFossilFuel
Www.PowerSave3400.com Power Save 1200/3200.../3400 Net Meter Solar!
Rated 0.00 | 21 Views
HHO Simple PWM - No LPM Flow? Good Product...ion!
Rated 4.05 | 79 Views
Affiliate Submitter: wwwtacnalcom
(video 17) FlipCup Fuel Cell - 6 Amps HHO,...Hydrogen, Hydroxy
Rated 3.76 | 109 Views
By hho4all
Generator Running on Hho Testing Pt.9
Rated 4.41 | 3,033 Views
Affiliate Submitter: d3adp001
Best HHO Generators Kits & PLANS - Hydroge...n Conversion Kit - Hybrid H20 Fuel Cell Instructions
Rated 3.99 | 855 Views
Affiliate Submitter: WaterPoweredCarKits
30 Amp HHO Pulse Width Modulator Assembled...and Ready for Install
Rated 3.53 | 3,086 Views
By HHO KING
HHO Generator or Joe Cell Construction
Rated 3.96 | 2,040 Views
Affiliate Submitter: ultio1
How To Builld An HHO Dry Cell - Make Hydro...gen Fuel Generator Plans
Rated 3.59 | 23,435 Views
By HybridMan
Rated 4.24 | 1,894 Views
Affiliate Submitter: RonL2524
2 Stroke (from 4) HHO Vacuum Theory Animat...ion (2)
Rated 3.30 | 814 Views
Affiliate Submitter: UnityEnergy